Close
(0) items
You have no items in your shopping cart.
All Categories
    Filters
    Preferences
    Search

    Sorry - this product is no longer available

    OASiS Control Panel with RF communications and wired inputs module

    €250.06 incl tax
    The JA-82KRC is a configuration of the JA-82K control panel that includes the JA-82R wireless communications module and the JA-82C wired inputs module. The JA 82K main board provides building-block-like modularity which allows functional extensions to be made by simply plugging-in the required modules.
    SKU: JA-82KRC
    Ship to
    *
    *
    Shipping Method
    Name
    Estimated Delivery
    Price
    No shipping options

    Features: The JA-82KRC provides 14 wired inputs and 50 wireless inputs (addresses). This configuration makes it possible that up to 50 wireless devices of the JA-8x can be enrolled. The following additional modules can be plugged-in:

    • JA-80Y - a GSM communicator which allows alarm reporting, ARC (alarm receiving centre) communication via GSM and remote access via a phone keypad or via the Internet (using the GSMLink web application).
    • JA-80V - a LAN / PSTN line communicator which allows alarm reporting via a fixed line, ARC communication via LAN (Ethernet) and remote access via a phone keypad or via the Internet (using the GSMLink web application).
    • JA-80X - a phone-line voice communicator which allows alarm voice-reporting, ARC communication and remote access via a telephone keypad.


    The modules can be used in combination except for the communicators where only the JA-80V and the JA-80X can be plugged in simultaneously.
    Application:

    • Power supply: 230 V / 50 Hz, max 0.1 A, CLASS PROTECTION II;
    • Backup-battery: 12 V, 1.3 or 2.6 Ah, typical battery lifetime approx. 5 years;
    • Backup power output: maximum continuous load 0.4 A, intermittent load 1 A for 15 mins max. ;
    • Number of wireless device addresses: 50;
    • Number of hard-wired inputs: 4 (or 14 with JA-82C plugged in) , double balanced inputs, with triggering and tamper functions, programmable section assignment and reactions;
    • External warning output EW*: switchable relay contact max. 0.5A;
    • Internal warning output IW*: switching to GND, max. 0.5A;
    • Programmable outputs PGX, PGY*: max. 0.1 A, switching to GND, programmable function;
    • Event memory: 255 latest events, including date and time stamping;
    • Communications frequency (JA-82R): 868 MHz;
    • Security grade: 2 according to EN 50131-1, EN 50131-6, and EN 50131-5-3;
    • Operating environment: II. Internal (-10 to +40°C) - compliant with EN 50131-1;
    • Radio emissions: ETSI EN 300220;
    • EMC: EN 50130-4,EN 55022;
    • Electrical safety: EN 60950-1;


    * these signals are also transmitted wirelessly to AC and UC receiver modules.

    Warning: For the easiest setting and supervision of the system, we recommend using the JA-80T or JA-80BT interface along with Olink software. The backup battery is not included!
    The console can be used with the SA-214/2.2 battery.

    Pack Details: The package includes:
    1x JA-82K
    1x JA-82R
    1xJA-82C

    Write your own review
    • Only registered users can write reviews
    *
    *
    • Bad
    • Excellent
    *
    *
    *
    *

    Features: The JA-82KRC provides 14 wired inputs and 50 wireless inputs (addresses). This configuration makes it possible that up to 50 wireless devices of the JA-8x can be enrolled. The following additional modules can be plugged-in:

    • JA-80Y - a GSM communicator which allows alarm reporting, ARC (alarm receiving centre) communication via GSM and remote access via a phone keypad or via the Internet (using the GSMLink web application).
    • JA-80V - a LAN / PSTN line communicator which allows alarm reporting via a fixed line, ARC communication via LAN (Ethernet) and remote access via a phone keypad or via the Internet (using the GSMLink web application).
    • JA-80X - a phone-line voice communicator which allows alarm voice-reporting, ARC communication and remote access via a telephone keypad.


    The modules can be used in combination except for the communicators where only the JA-80V and the JA-80X can be plugged in simultaneously.
    Application:

    • Power supply: 230 V / 50 Hz, max 0.1 A, CLASS PROTECTION II;
    • Backup-battery: 12 V, 1.3 or 2.6 Ah, typical battery lifetime approx. 5 years;
    • Backup power output: maximum continuous load 0.4 A, intermittent load 1 A for 15 mins max. ;
    • Number of wireless device addresses: 50;
    • Number of hard-wired inputs: 4 (or 14 with JA-82C plugged in) , double balanced inputs, with triggering and tamper functions, programmable section assignment and reactions;
    • External warning output EW*: switchable relay contact max. 0.5A;
    • Internal warning output IW*: switching to GND, max. 0.5A;
    • Programmable outputs PGX, PGY*: max. 0.1 A, switching to GND, programmable function;
    • Event memory: 255 latest events, including date and time stamping;
    • Communications frequency (JA-82R): 868 MHz;
    • Security grade: 2 according to EN 50131-1, EN 50131-6, and EN 50131-5-3;
    • Operating environment: II. Internal (-10 to +40°C) - compliant with EN 50131-1;
    • Radio emissions: ETSI EN 300220;
    • EMC: EN 50130-4,EN 55022;
    • Electrical safety: EN 60950-1;


    * these signals are also transmitted wirelessly to AC and UC receiver modules.

    Warning: For the easiest setting and supervision of the system, we recommend using the JA-80T or JA-80BT interface along with Olink software. The backup battery is not included!
    The console can be used with the SA-214/2.2 battery.

    Pack Details: The package includes:
    1x JA-82K
    1x JA-82R
    1xJA-82C